49
Camera interfaces
Control signals
The inputs and outputs of the camera can be configured by software. The differ-
ent modes are described below.
Inputs
Input/output pin control
All input and output signals that pass the I/O connector are controlled by the
I/O strobe commands.
Outputs
Output features are configured by software. Any signal can be placed on any
output. The main features of the output signals are described below:
Figure 39: Input block diagram
Signal Description
GPO Configured to be a general purpose output, control is assigned to
SyncOutGpoLevels.
AcquisitionTriggerReady Active once the camera has been recognized by the host PC and is ready to start
acquisition.
FrameTriggerReady Active when the camera is in a state that will accept the next frame trigger.
FrameTrigger Active when an image has been initiated to start. This is a logic trigger
internal to the camera, which is initiated by an external trigger or software
trigger event.
Exposing Exposing – active for the duration of sensor exposure.
FrameReadout Active during frame readout, i.e., the transferring of image data from the CCD
to the camera memory.
Table 26: Output signals
Polarity
selectable
via software
Input state
Input signal
Optocoupler
LP filter