Camera interfaces
Mako output description
Mako block diagram
Figure 36: Mako output block diagram
Caution
Maximum 20 mA per output
Camera Out Power 30 V may damage the camera
Camera Out Power Resistor value*
5V 1.0k
at 5 mA minimum required
current draw
12 V 2.4 k
24 V 4.7 k
* Resistor required if Out1/2/3 connected to a device with < 5 mA draw,
i.e. high impedance
Figure 37: Mako: Camera Out Power and external resistor
ExternalInternal
Camera Out Power
Out1
Out2
R
R
R
Out3