Allied Vision Technologies MF-145B2 Instruction Manual Page 78

  • Download
  • Add to my manuals
  • Print
  • Page
    / 237
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 77
Marlin Technical ManualV.2.7.0
78
Description of the data path
Loading an LUT into the camera
Loading the LUT is carried out through the data exchange buffer called
GPDATA_BUFFER. As this buffer can hold a maximum of 2 kB, and a complete LUT
at 1024 x 8 bit is 1 kB, programming can take place in a one block write step. The
flow diagram below shows the sequence required to load data into the camera.
Note
The input value is the most significant 10-bit value from
the digitizer. The gamma LUT of the CCD models outputs
the most significant 8 bit as shown above.
As gamma correction for the CCD models is also imple-
mented via the look-up table, it is not possible to use a
different LUT when gamma correction is enabled.
With all CCD models, the user LUT will be overwritten
when Gamma is enabled and vice versa.
CMOS models have the gamma function built in the sen-
sor, so that it won’t be overwritten.
LUT content is by default volatile, use user set function-
ality to store the LUT permanently in the camera.
Figure 39: Loading an LUT
Note
Configuration
To configure this feature in an advanced register: See
Table 106: Advanced register: LUT on page 205.
For information on GPDATA_BUFFER: See Chapter
GPDATA_BUFFER on page 225.
Query Limits from
Register:
LUT_INFO and
GPDATA_INFO
Set EnableMemWR
to true (1)
Set AddrOffset to 0
Write LUT data in
GPDATA_BUFFER
Set EnableMemWR
to false (0)
Page view 77
1 2 ... 73 74 75 76 77 78 79 80 81 82 83 ... 236 237

Comments to this Manuals