Allied Vision Technologies MF-145B2 Instruction Manual Page 211

  • Download
  • Add to my manuals
  • Print
  • Page
    / 237
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 210
Marlin Technical ManualV.2.7.0
211
Configuration of the camera
Having generated the correction data it is possible to separately control the
blemish pixel correction with the help of the following register:
Input/output pin control
Register Name Field Bit Description
0xF1000294 BLEMISH_CONTROL Presence_Inq [0] Indicates presence of this fea-
ture (read only)
ComputeError [1] see DSNU_CONTROL
--- [2..3]
ShowImage [4] see DSNU_CONTROL
ComputeData [5] see DSNU_CONTROL
ON_OFF [6] blemish correction On/Off
ON: High
Default: OFF
Busy [7] see DSNU_CONTROL
SaveData [8] Save blemish correction data
to flash
LoadData [9] Load blemish correction data
from flash
ZeroData [10] see DSNU_CONTROL
--- [11..23] Reserved
GrabCount [24..31] see DSNU_CONTROL
Table 112: Advanced register: Blemish
Note
See Chapter Input/output pin control on page 50
See Chapter IO_INP_CTRL 1-2 on page 50
See Chapter IO_OUTP_CTRL 1-2 on page 54
See Chapter Output modes on page 55