Configuration of the camera
DSNU control
The table below shows the advanced register map, required to control this func-
tionality.
Register Name Field Bit Description
0xF1000290 DSNU_CONTROL Presence_Inq [0] Indicates presence of this fea-
ture (read only)
ComputeError [1] ON: Error on computing DSNU
correction, e.g. sequence
mode active (read only)
OFF: No Error
--- [2..3] Reserved
ShowImage [4] Show correction data as image
ComputeData [5] Compute new DSNU correction
data
ON_OFF [6] DSNU correction On/Off
ON: High
OFF: Low
Default: OFF
Busy [7] Computation in progress
SaveData [8] Save DSNU correction data to
flash
LoadData [9] Load DSNU correction data
from flash
ZeroData [10] Zero DSNU correction data
--- [11..23] Reserved
GrabCount [24..31] Number of images
Table 111: Advanced register: DSNU