Controlling image capture
Microcontroller-Sync is an internal signal. It is generated by the microcontroller
to initiate a trigger. This can either be a direct trigger or a release for ExSync if
the camera is externally triggered.
End of exposure to first packet on the bus
After the exposure, the CCD or CMOS sensor is read out; some data is written into
the FRAME_BUFFER before being transmitted to the bus.
The time from the end of exposure to the start of transport on the bus is:
500 μs ± 62.5 μs
This time 'jitters with the cycle time of the bus (125 μs).
Figure 74: Data flow and timing after end of exposure
OneShot Command
C-> ExSync
Integration-Start
Timebase Reg.
X
Shutter-Reg.
Offset
Processing Delay
< 250µs
<= 8µs
Timebase x Shutter + Offset = Exposure Time
First Packet on Bus
<= 500µs
+/-62.5 µs
Exposure
Marlin F-033: 12 µs
Marlin F-046 12µs
Marlin F-080: 30 µs
Marlin F-080-30fps: 17 µs
Marlin F-145: 26µs
Marlin F-146: 26 µs
Marlin F-201: 39 µs
Marlin F-131: < 1 µs