Configuration of the camera
Auto shutter control
The table below illustrates the advanced register for auto shutter control. The
purpose of this register is to limit the range within which auto shutter operates.
Auto gain control
The table below illustrates the advanced register for auto gain control.
MinValue and MaxValue limits the range the auto gain feature is allowed to use
for the regulation process. Both values are initialized with the minimum and
maximum value defined in the standard GAIN_INQ register.
Changing the auto gain range might not affect the regulation, if the regulation
is in a stable condition and no other condition affecting the image brightness is
changed.
If both auto gain and auto shutter are enabled and if the gain is at its lower
boundary and shutter regulation is in progress, decreasing the lower auto gain
boundary has no effect on auto gain/shutter regulation as long as auto shutter
regulation is active.
Both values can only be changed within the range defined by the standard
GAIN_INQ register.
Register Name Field Bit Description
0xF1000360 AUTOSHUTTER_CTRL Presence_Inq [0] Indicates presence of this fea-
ture (read only)
--- [1..31] Reserved
0xF1000364 AUTOSHUTTER_LO Min Value [0..31] Minimum value
0xF1000368 AUTOSHUTTER_HI Max Value [0..31] Maximum value
Table 114: Advanced register: Auto shutter control
Register Name Field Bit Description
0xF1000370 AUTOGAIN_CTRL Presence_Inq [0] Indicates presence of this
feature (read only)
--- [1..3] Reserved
Max Value [4..15] Maximum auto gain value
--- [16..19] Reserved
Min value [20..31] Minimum auto gain value
Table 115: Advanced register: Auto gain control