Technical ManualAVT GigE Vision CamerasV2.0.326 November 2013Allied Vision Technologies GmbHTaschenweg 2aD-07646 Stadtroda, GermanyAVT Prosilica GE
Prosilica GE Technical Manual V2.0.310IntroductionCleaning with airBlow directly on the contaminated surface with moderate pressure, clean com-presse
Prosilica GE Technical Manual V2.0.311ConformityConformityAllied Vision Technologies declares under its sole responsibility that all stan-dard camera
Prosilica GE Technical Manual V2.0.312SpecificationsSpecificationsProsilica GE680/680CFeature SpecificationResolution 640 x 480Sensor Truesense KAI-0
Prosilica GE Technical Manual V2.0.313Specifications Figure 1: Prosilica GE680 monochrome spectral response Figure 2: Prosilica GE680C color spectral
Prosilica GE Technical Manual V2.0.314SpecificationsProsilica GE1050/1050CFeature SpecificationResolution 1024 x 1024Sensor Truesense KAI-01050 Type
Prosilica GE Technical Manual V2.0.315Specifications Figure 3: Prosilica GE1050 monochrome spectral response Figure 4: Prosilica GE1050C color spectr
Prosilica GE Technical Manual V2.0.316SpecificationsProsilica GE1650/1650CFeature SpecificationResolution 1600 x 1200Sensor Truesense KAI-2020 Type C
Prosilica GE Technical Manual V2.0.317Specifications Figure 5: Prosilica GE1650 monochrome spectral response Figure 6: Prosilica GE1650C color spectr
Prosilica GE Technical Manual V2.0.318SpecificationsProsilica GE1660/1660CFeature SpecificationResolution 1600 x 1200Sensor Truesense KAI-2050 Type C
Prosilica GE Technical Manual V2.0.319Specifications Figure 7: Prosilica GE1660 monochrome spectral response Figure 8: Prosilica GE1660C color spectr
Prosilica GE Technical Manual V2.0.32Legal noticeFor customers in the U.S.A.This equipment has been tested and found to comply with the limits for a
Prosilica GE Technical Manual V2.0.320SpecificationsProsilica GE1900/1900CFeature SpecificationResolution 1920 x 1080Sensor Truesense KAI-2093 Type C
Prosilica GE Technical Manual V2.0.321Specifications Figure 9: Prosilica GE1900 monochrome spectral response Figure 10: Prosilica GE1900C color spect
Prosilica GE Technical Manual V2.0.322SpecificationsProsilica GE1910/1910CFeature SpecificationResolution 1920 x 1080Sensor Truesense KAI-02150Type C
Prosilica GE Technical Manual V2.0.323Specifications Figure 11: Prosilica GE1910 monochrome spectral response Figure 12: Prosilica GE1910C color spec
Prosilica GE Technical Manual V2.0.324SpecificationsProsilica GE2040/2040CFeature SpecificationResolution 2040 x 2048Sensor Truesense KAI- 04022Type
Prosilica GE Technical Manual V2.0.325Specifications Figure 13: Prosilica GE2040 monochrome spectral response Figure 14: Prosilica GE2040C color spec
Prosilica GE Technical Manual V2.0.326SpecificationsProsilica GE4000/4000CFeature SpecificationResolution 4008 x 2972Sensor Truesense KAI-11002 Type
Prosilica GE Technical Manual V2.0.327Specifications Figure 15: Prosilica GE4000 monochrome spectral response Figure 16: Prosilica GE4000C color spec
Prosilica GE Technical Manual V2.0.328SpecificationsProsilica GE4900/4900C Feature SpecificationResolution 4872 x 3248Sensor Truesense KAI-16000 Type
Prosilica GE Technical Manual V2.0.329Specifications Figure 17: Prosilica GE4900 monochrome spectral response Figure 18: Prosilica GE4900C color spec
Prosilica GE Technical Manual V2.0.33ContentsContacting Allied Vision Technologies ... 5Introduction
Prosilica GE Technical Manual V2.0.330Camera attribute highlights Camera attribute highlights AVT cameras support a number of standard and extended f
Prosilica GE Technical Manual V2.0.331FiltersFiltersAll Prosilica GE color models are equipped with an infrared block filter (IR fil-ter). This filte
Prosilica GE Technical Manual V2.0.332Camera dimensionsCamera dimensionsProsilica GE C-Mount (adjustable)GE680/680C, GE1050/1050C, GE1650/1650C, GE16
Prosilica GE Technical Manual V2.0.333Camera dimensionsProsilica GE F-Mount: GE2040/2040C Figure 21: Prosilica GE F-Mount mechanical dimensions*Nomi
Prosilica GE Technical Manual V2.0.334Camera dimensionsProsilica GE large format F-Mount: GE4000/4000C, GE4900/4900C Figure 22: Prosilica GE large fo
Prosilica GE Technical Manual V2.0.335Camera dimensionsTripod adapterA Prosilica GE camera can be mounted on a camera tripod by using a mounting plat
Prosilica GE Technical Manual V2.0.336Camera dimensionsOptical flange focal distanceOptical flange focal distance is the optical distance from the mo
Prosilica GE Technical Manual V2.0.337Camera dimensionsF-Mount cross sectionTable 14 presents flange focal distance values for Prosilica GE cameras w
Prosilica GE Technical Manual V2.0.338Camera dimensionsAdjustment of C-MountThe C-Mount or CS-Mount is adjusted at the factory and should not require
Prosilica GE Technical Manual V2.0.339Camera dimensionsAdjustment of F-MountThe F-Mount is adjusted at the factory and should not require adjusting.
Prosilica GE Technical Manual V2.0.34Adjustment of F-Mount...
Prosilica GE Technical Manual V2.0.340Camera interfacesCamera interfacesThis chapter provides information on Gigabit Ethernet port, inputs and output
Prosilica GE Technical Manual V2.0.341Camera interfacesGigabit Ethernet portThe Gigabit Ethernet port conforms to the IEEE 802.3 1000BASE-T standard
Prosilica GE Technical Manual V2.0.342Camera interfacesCamera I/O connector pin assignment The general purpose I/O port uses a Hirose HR10A-10R-12SB
Prosilica GE Technical Manual V2.0.343Camera interfacesI/O definitionCamera power The Prosilica GE camera family supports a wide input power voltage
Prosilica GE Technical Manual V2.0.344Camera interfacesThe Mini-SMB trigger input is internally connected to the In 1 of the general purpose I/O port
Prosilica GE Technical Manual V2.0.345Camera interfacesOut 2 and Out 3Out 2 and Out 3 can be configured to active high or active low. The internal ca
Prosilica GE Technical Manual V2.0.346Camera interfacesCamera I/O connector internal circuit diagram Figure 30: Prosilica GE internal circuit diagram
Prosilica GE Technical Manual V2.0.347Camera interfacesCamera I/O connector external circuit exampleThe trigger circuit is connected to a Texas Instr
Prosilica GE Technical Manual V2.0.348Camera interfacesIn 1, Out 1 external circuit exampleThe trigger circuit is connected to a Texas Instruments SN
Prosilica GE Technical Manual V2.0.349Camera interfacesTrigger timing diagramNotes on triggering Figure 33: Prosilica GE internal signal timing wavef
Prosilica GE Technical Manual V2.0.35Contacting Allied Vision TechnologiesContacting Allied Vision TechnologiesInfo• Technical information:http://ww
Prosilica GE Technical Manual V2.0.350Camera interfacesTrigger rules•The end of exposure will always trigger the next readout.•The end of exposure mu
Prosilica GE Technical Manual V2.0.351Firmware updateFirmware updateFirmware updates are carried out via the GigE connection. AVT provides an applica
Prosilica GE Technical Manual V2.0.352Resolution and ROI frame ratesResolution and ROI frame ratesThis section provides the performance information w
Prosilica GE Technical Manual V2.0.353Resolution and ROI frame ratesProsilica GE1050Prosilica GE1650 Figure 35: Frame rate vs. height for Prosilica G
Prosilica GE Technical Manual V2.0.354Resolution and ROI frame ratesProsilica GE1660Prosilica GE1900 Figure 37: Frame rate vs. height for Prosilica G
Prosilica GE Technical Manual V2.0.355Resolution and ROI frame ratesProsilica GE1910Prosilica GE2040 Figure 39: Frame rate vs. height for Prosilica G
Prosilica GE Technical Manual V2.0.356Resolution and ROI frame ratesProsilica GE4000Prosilica GE4900 Figure 41: Frame rate vs. height for Prosilica G
Prosilica GE Technical Manual V2.0.357Resolution and ROI frame ratesProsilica GE model comparison Figure 43: Maximum frame rate vs. height for selec
Prosilica GE Technical Manual V2.0.358Description of the data pathDescription of the data pathThe following diagrams illustrate the data flow and the
Prosilica GE Technical Manual V2.0.359Additional referencesAdditional referencesProsilica GE webpagehttp://www.alliedvisiontec.com/us/products/camera
Prosilica GE Technical Manual V2.0.36IntroductionIntroductionThis AVT Prosilica GE Technical Manual describes in depth the technical speci-fications
Prosilica GE Technical Manual V2.0.360IndexIndexAAdjustingC-Mount ... 38F-Mount ...
Prosilica GE Technical Manual V2.0.361IndexSSensor row readout cycles ... 50Specifications ...
Prosilica GE Technical Manual V2.0.37IntroductionConventions used in this manualTo give this manual an easily understandable layout and to emphasize
Prosilica GE Technical Manual V2.0.38IntroductionPrecautionsCautionThis symbol highlights important instructions. You have to fol-low these instruct
Prosilica GE Technical Manual V2.0.39IntroductionCleaning opticsIdentifying debrisDebris on the image sensor or optical components appears as a darke